Cable Design Parameters

Balaji Part No. Size (sq mm) Construction Max Conductor Dia (mm) Resistance @20°C (mΩ/m) Insulation Thickness (mm) Outer Diameter (mm) Current Rating @30°C (Amps)
CB-0.22 0.22 7/0.20 0.7 Max: 84.80 Nom: 0.60 Max: 2.00 / Min: 1.70 8
CB-0.35 0.35 12/0.20 0.9 Max: 54.40 Nom: 0.60 Max: 2.10 / Min: 1.80 13
CB-0.50 0.5 16/0.20 1.1 Max: 37.10 0.60 / 0.48 Max: 2.30 / Min: 2.00 23
CB-0.75 0.75 24/0.20 1.3 Max: 24.70 0.60 / 0.48 Max: 2.50 / Min: 2.20 30
CB-1.00 1 32/0.20 1.5 Max: 18.50 0.60 / 0.48 Max: 2.70 / Min: 2.40 36
CB-2.00 2 28/0.30 2 Max: 9.42 0.60 / 0.48 Max: 3.30 / Min: 3.00 44
CB-2.50 2.5 50/0.25 2.2 Max: 7.60 0.70 / 0.56 Max: 3.60 / Min: 3.30 61
CB-4.00 4 56/0.30 2.8 Max: 4.71 0.80 / 0.64 Max: 4.40 / Min: 4.00 81
CB-6.00 6 84/0.30 3.4 Max: 3.14 0.80 / 0.64 Max: 5.00 / Min: 4.60 104
CB-8.00 8 50/0.45 or 240/0.21 or 1650/0.08 4.3 Max: 2.38 0.80 / 0.64 Max: 5.90 / Min: 5.00 126
CB-10.00 10 80/0.40 or 320/0.20 4.5 Max: 1.82 1.00 / 0.80 Max: 6.50 / Min: 5.90 148
CB-12.00 12 96/0.40 5.4 Max: 1.52 1.00 / 0.80 Max: 7.40 / Min: 6.60 172
CB-16.00 16 126/0.40 or 512/0.20 5.8 Max: 1.16 1.00 / 0.80 Max: 8.30 / Min: 7.70 197
CB-20.00 20 610/0.20 6.9 Max: 0.955 1.10 / 0.88 Max: 9.10 / Min: 8.10 220
CB-25.00 25 196/0.40 or 790/0.2 7.2 Max: 0.743 1.30 / 1.04 Max: 10.40 / Min: 9.40 263
CB-35.00 35 276/0.40 or 1070/0.20 8.5 Max: 0.527 1.30 / 1.04 Max: 11.60 / Min: 9.60 327
CB-40.00 40 308/0.40 or 1200/0.20 9.6 Max: 0.473 1.40 / 1.12 Max: 12.40 / Min: 11.20 370
CB-50.00 50 396/0.40 or 1600/0.20 10.5 Max: 0.368 1.50 / 1.20 Max: 13.50 / Min: 11.50 413
CB-70.00 70 360/0.40 12.5 Max: 0.259 1.50 / 1.20 Max: 15.50 / Min: 13.50 531
CB-95.00 95 475/0.50 14.8 Max: 0.196 1.60 / 1.28 Max: 18.00 / Min: 16.00 623
CB-150.00 150 741/0.50 15.9 Max: 0.129 2.2 Nom: 21.90 ± 1.50 723

Disclaimer :

The information contained in this datasheet is for guidance only and is subject to change without notice or liability. All the information is provided in good faith and is believed to be correct at the time of publication. When selecting the cable accessories, please note that actual cable dimensions may vary due to manufacturing tolerances.