EnDuraTM / FLR12Y / FLR13Y Cables, TPE insulated 150°C
Applications
- Any critical application that requires temperature rating greater than 125˚C.
- Engine management systems.
- Engine compartment wiring systems.
- Magneto wiring systems.
- Lamp wiring systems.
- Gear Shift Indicator wiring systems.
- Ignition Coil wiring systems.
- ISG Application
Features
- Suitable for use directly in high temperature areas without use of additional protection or heat shields due to excellent thermal and mechanical properties at high temperature.
- Very good abrasion resistance
- Passes high temperature pressure test at 200°C
- (Class F requirement)
- Passes 175°C for 3000 hours(Class E requirement)
Note: The product has limited Resistance to Battery Acid
Technical Data
Standard | ISO 6722 Class-D / ISO 19642 |
Nominal Voltage | 60 & 600 V |
Temperature Range | Flexible -40°C to +150°C |
Certifications & Compliance
Cable Design Parameters
Type -A
Metric Cross Sectional Area (Sq .mm ) | No of Strand /Strand Diameter (mm) | Maximum Conductor Resistance at 20°C (ohm/km ) | Nominal Insulation Thickness | Minimum Cable Diameter | Maximum Cable Diameter |
Plain Copper | |||||
0.22 | 7/0.21 | 84.8 | 0.25 | 1.10 | 1.20 |
0.35 | 7/0.27 | 54.4 | 0.25 | 1.20 | 1.30 |
0.50 | 19/0.19 | 37.1 | 0.28 | 1.40 | 1.60 |
0.75 | 19/0.24 | 24.7 | 0.30 | 1.70 | 1.90 |
1.00 | 19/0.27 | 18.5 | 0.30 | 1.90 | 2.10 |
1.25 | 19/0.30 | 14.9 | 0.30 | 2.10 | 2.30 |
1.50 | 19/0.33 | 12.7 | 0.30 | 2.20 | 2.40 |
2.00 | 19/0.38 | 9.42 | 0.35 | 2.50 | 2.80 |
2.50 | 37/0.28 | 7.60 | 0.35 | 2.70 | 3.00 |
4.00 | 37/0.38 | 4.71 | 0.40 | 3.40 | 3.70 |
Type -B
0.35 | 12/0.21 | 54.4 | 0.25 | 1.20 | 1.40 |
0.50 | 16/0.21 | 37.1 | 0.28 | 1.40 | 1.60 |
0.75 | 24/0.21 | 24.7 | 0.30 | 1.70 | 1.90 |
1.00 | 32/0.21 | 18.5 | 0.30 | 1.90 | 2.10 |
1.50 | 30/0.26 | 12.7 | 0.30 | 2.20 | 2.40 |
2.50 | 50/0.26 | 7.60 | 0.35 | 2.70 | 3.00 |
4.00 | 56/0.31 | 4.71 | 0.40 | 3.40 | 3.70 |
Disclaimer :
REACH compliance should be considered as customer specific requirement and must be specified at time enquiry if required. The information contained in this datasheet is for guidance only and is subject to change without notice or liability. All the information is provided in good faith and is believed to be correct at the time of publication. When selecting the cable accessories, please note that actual cable dimensions may vary due to manufacturing tolerances.