FLYY, Single Core 105°C Pvc Insulated Cables
Applications
- These cables are ideal for use in automotive applications where higher current carrying capacity and mechanical strength are required.
Features
- The special cable construction, offers higher mechanical strength without compromising with the cable flexibility. The cable is suitable for rugged applications across the extreme temperature range.
- Sheath options: firmly bonded or separable.
Technical Data
Certifications & Compliance
Cable Design Parameters
Metric Cross Sectional Area (Sq .mm ) | No of Strand /Strand Diameter
(mm) |
Maximum Conductor Resistance at 20°C (ohm/km ) | Insulation |
Sheath |
||||
Plain Copper | Sn Plated Copper | Nominal Wall Thickness (mm) | Nominal Core O.D (mm) | Nominal Sheath Thickness
(mm) |
Minimum O.D
(mm) |
Maximum
O.D (mm) |
||
0.50 | 16/0.21 | 37.1 | 38.2 | 0.60 | 2.10 | 0.40 | 2.70 | 3.10 |
0.75 | 24/0.21 | 24.7 | 25.4 | 0.60 | 2.30 | 0.40 | 3.00 | 3.30 |
1.00 | 32/0.21 | 18.5 | 19.1 | 0.60 | 2.50 | 0.40 | 3.20 | 3.60 |
1.50 | 30/0.26 | 12.7 | 13.0 | 0.60 | 2.80 | 0.50 | 3.70 | 4.10 |
2.00 | 28/0.31 | 9.42 | 9.69 | 0.60 | 3.00 | 0.50 | 3.90 | 4.30 |
2.50 | 50/0.26 | 7.60 | 7.82 | 0.70 | 3.50 | 0.50 | 4.30 | 4.80 |
Disclaimer :
REACH compliance should be considered as customer specific requirement and must be specified at time enquiry if required. The information contained in this datasheet is for guidance only and is subject to change without notice or liability. All the information is provided in good faith and is believed to be correct at the time of publication. When selecting the cable accessories, please note that actual cable dimensions may vary due to manufacturing tolerances.