FLRYH, Single Core 105°C Cables

AVH & AVSH Cable

Applications

  • This PVC insulated single-core cable with symmetrical conductor structure and thin wall is used for automobiles, Motorcycles electrical equipment in high temperature condition.
AVH & AVSH Cable Product Construction

Features

  • The lead free, PVC polymer, offers excellent resistance to petrol, chemicals, and abrasion, and in addition is suitable for both low and high temperature applications.
  • Flexible Strand Structure.
Balajiwires Quick Quote

Technical Data

Standard ISO 6722 Class-B , LV 112-1
Nominal Voltage 60 V and 600 V
Temperature Range Flexible  -40°C to +105°C
Download Product Details

Certifications & Compliance

Certifications & Compliance

Cable Design Parameters

Metric Cross Sectional Area (Sq. mm ) No of Strand /Strand Diameter (mm) Diameter of the Conductor Maximum (mm)  Maximum Conductor Resistance at 20°C  (ohm/km ) Minimum Insulation Thickness (mm) Minimum Cable Diameter (mm) Maximum Cable Diameter (mm)
0.35 45/0.11 0.90 54.4 0.20 1.20 1.40
0.50 64/0.11 1.00 37.1 0.22 1.40 1.60
0.75 96/0.11 1.20 24.7 0.24 1.70 1.90
1.00 126/0.11 1.35 18.5 0.24 1.90 2.10
1.50 196/0.11 1.70 12.7 0.24 2.20 2.40
2.50 315/0.11 2.20 7.60 0.28 2.70 3.00
4.00 126/0.21 2.75 4.71 0.32 3.40 3.70
6.00 189/0.21 3.40 3.14 0.32 4.00 4.30
10.00 324/0.21 4.50 1.82 0.48 5.40 5.80
16.00 518/0.21 5.50 1.16 0.52 6.50 7.00
25.00 798/0.21 7.00 0.743 0.64 8.20 8.80
35.00 1107/0.21 8.30 0.527 0.80 9.80 10.50

Disclaimer :

REACH compliance should be considered as customer specific requirement and must be specified at time enquiry if required. The information contained in this datasheet is for guidance only and is subject to change without notice or liability. All the information is provided in good faith and is believed to be correct at the time of publication. When selecting the cable accessories, please note that actual cable dimensions may vary due to manufacturing tolerances.