Safety Applications MultiCore, Upto 4 core PVC Insulated & PVC Sheathed with options of Sheilding
Applications
- Impact protection (airbag)
- Restraint systems (belt)
- Active headrest, seats, engine cover (pre/in crash)
- Locking systems, clamping protection
- Chassis safety
- Pre-impact warning sensors, distance controller (collision avoidance)
Features
- Excellent processibility
- Customised solutions
Technical Data
Standard | Compliant with ISO 6722, LV 112, ISO 14572, LV 212, JASO and customer specifications. |
PVC | -40 oC to +105 oC / -40 oC to +125 oC, |
Certifications & Compliance
Cable Design Parameters
Cable structure | No of strand | Max single wire dia (mm) | Nominal Conductor diameter (mm) | Nominal diameter of cores (mm) | Nominal outer cable diameter (mm) | Shield type | Insulation material | Jacket material | Conductor resistance (mΩ/m ) | Temperature Range (°C) |
PVC Round Cable | ||||||||||
2×0.35-A | 7 | 0.26 | 0.75 | 1.25 | 5.45 | – | PVC | PVC | 54.4 | -40 to +105 |
2×0.35-A | 7 | 0.26 | 0.75 | 1.30 | 3.75 | – | PVC | PVC | 54.4 | -40 to +105 |
2×0.35-A | 7 | 0.26 | 0.75 | 1.25 | 3.50 | – | PVC | PVC | 54.4 | -40 to +105 |
2×0.35-A | 7 | 0.26 | 0.75 | 1.25 | 4.00 | – | PVC | PVC | 54.4 | -40 to +105 |
3×0.35-A | 7 | 0.26 | 0.75 | 1.25 | 3.90 | – | PVC | PVC | 54.4 | -40 to +105 |
2×0.5-A | 19 | 0.19 | 0.90 | 1.55 | 4.40 | – | PVC | PVC | 37.1 | -40 to +105 |
2×0.5-B | 16 | 0.21 | 0.90 | 1.70 | 4.50 | – | PVC | PVC | 37.1 | -40 to +105 |
2×0.5-A | 19 | 0.19 | 0.90 | 1.55 | 4.45 | – | PVC | PVC | 37.1 | -40 to +105 |
2×0.5/7 | 7 | 0.31 | 0.90 | 1.70 | 4.45 | – | PVC | PVC | 37.1 | -40 to +105 |
2×0.5-A | 19 | 0.19 | 0.90 | 1.55 | 4.80 | – | PVC | PVC | 37.1 | -40 to +105 |
2×0.5sn-A | 19 | 0.19 | 0.90 | 1.55 | 4.45 | – | PVC | PVC | 38.2 | -40 to +105 |
2×0.5sn-A | 19 | 0.19 | 0.90 | 1.55 | 4.25 | – | PVC | PVC | 38.2 | -40 to +105 |
3×0.5-A | 19 | 0.19 | 0.90 | 1.55 | 4.50 | – | PVC | PVC | 37.1 | -40 to +105 |
2×0.5sn+0.5 | 19 | 0.19 | 0.90 | 1.55 | 4.50 | – | PVC | PVC | 38.2 | -40 to +105 |
4×0.5-A | 19 | 0.19 | 0.90 | 1.50 | 4.80 | – | PVC | PVC | 37.1 | -40 to +105 |
PVC Special Cables | ||||||||||
4×0.35+2×2.5 | 12/50 | 0.21/0.26 | 0.75/2.00 | 1.30/2.70 | 6.85 | – | PVC | PVC | 54.4 | -40 to +105 |
PVC flat cables | ||||||||||
2×0.35-A | 7 | 0.26 | 0.75 | 1.25 | 3.90 X 2.60 | – | PVC | PVC | 54.4 | -40 to +105 |
2×0.35-A | 7 | 0.26 | 0.75 | 1.25 | 4.10 X 2.80 | – | PVC | PVC | 54.4 | -40 to +105 |
2×0.35sn-A | 7 | 0.26 | 0.75 | 1.25 | 4.10 X 2.80 | – | PVC | PVC | 55.5 | -40 to +105 |
2×0.5-A | 7 | 0.26 | 0.75 | 1.55 | 4.10 X 2.80 | – | PVC | PVC | 37.1 | -40 to +105 |
2×0.5-B | 16 | 0.21 | 0.90 | 1.55 | 3.80 X 2.25 | – | PVC | PVC | 37.1 | -40 to +105 |
2×0.5-A | 19 | 0.19 | 0.90 | 1.55 | 4.10 X 2.80 | – | PVC | PVC | 37.1 | -40 to +105 |
PVC 125 ̊C | ||||||||||
2X0.5-A | 19 | 0.19 | 0.90 | 1.55 | 4.40 | – | PVC | PVC | 37.1 | -40 to +125 |
PVC shielded | ||||||||||
2X0.35+DW | 7 | 0.26 | 0.75 | 1.25 | 3.70 | B | PVC | PVC | 54.4 | -40 to +105 |
Disclaimer :
REACH compliance should be considered as customer specific requirement and must be specified at time enquiry if required. The information contained in this datasheet is for guidance only and is subject to change without notice or liability. All the information is provided in good faith and is believed to be correct at the time of publication. When selecting the cable accessories, please note that actual cable dimensions may vary due to manufacturing tolerances.