Multicore Comfort Application, Upto 6 Core PVC / TPE-E / PP Insulated & PVC / TPE Sheathed with options of Sheilding, Taping & Drain Wire

Comfort Application

Applications

  • Seat systems, power windows, mirror wiring.
  • Heating, ventilation and climate control systems.
  • Consumer electronics.
  • Car phone.
  • Convertible roof, tailgate and sun roof systems.
  • Park assistance.
  • Driver authentication system.
Comfort Application Product Construction

Features

  • Customer-specific cables available
  • Shielded versions
  • Certified according to international standards
Balajiwires Quick Quote

Technical Data

Standard Compliant with ISO 6722, LV 112, ISO 14572, LV 212, JASO & customer specifications.
Insulation options – PVC -40 oC to +90 oC / +105 oC / +125 oC
Insulation options – TPE-E,TPE-U -40 oC to +90 oC / +105 oC / +125 oC / +175°C
Insulation options – PP -40 oC to +90 oC / +105 oC / +125 oC
Download Product Details

Certifications & Compliance

Comfort Application Certifications & Compliance

Cable Design Parameters

Cable structure No of strands Max single wire dia  in mm Nominal Conductor diameter Nominal diameter of cores     in mm Nominal outer cable diameter  in mm Shield type Insulation material Jacket material Conductor resistance   (mΩ/m ) Indicative Temperature Range (°C)
PVC Round Cable
2×0.75 24 0.21 1.10 1.80 4.60 PVC PVC 24.7
4×0.5 19 0.19 0.90 1.50 5.30 PVC PVC 37.1 -40 to +105/125
3×0.5 19 0.19 0.90 1.55 4.70 PVC PVC 37.1 -40 to +105/125
5×0.35 Flex 45 0.11 0.80 1.30 4.70 PVC PVC 54.4 -40 to +105/125
PVC Special Cable
3×0.5 16 0.21 1.00 1.95 5.40 PVC PVC 36.7 -50 to +90/105/125
PVC 125°C round/flat
2×0.75 24 0.21 1.10 1.80 4.80 PVC PVC 24.7 -40 to 125
4×0.22 7 0.21 0.60 1.10 5.60 x 2.15 TPE-E PVC 84.8 -40 to 125
Special cable unshielded
4×0.35 45 0.11 0.80 1.30 5.80 TPE-E TPE-U 54.4 -40 to 125/150
PVC shielded
3×0.35+DW 19 0.16 0.90 1.30 4.20 C PVC PVC 54.4 -40 to 105/125
2×0.35+DW 7 0.26 0.75 1.25 3.70 B PVC PVC 55.5 -40 to 105/125

4×0.5+

DW

16 0.21 1.00 1.55 5.60 B PVC PVC 37.1 -40 to 105/125

6×0.5+

DW

19 0.19 0.90 1.55 6.40 B PVC PVC 37.1 -40 to 105/125
2×3+DW 98 0.21 2.20 3.10 6.80 C PVC PVC 6.15 -40 to 105/125
4×0.22 7 0.21 0.60 1.05 3.50 B PVC PVC 84.8 -40 to 105/125
2x2x0.75+DW 24 0.21 1.10 1.75 6.90 B PVC PVC 24.7 -40 to 105/125
2×0.35 12 0.21 0.80 1.35 4.40 C PVC PVC 54.4 -40 to 105/125
4×0.35 7 0.26 0.75 1.25 5.30 C PVC PVC 54.4 -40 to 105/125
2×0.5 19 0.19 0.90 1.55 4.80 B+C PVC PVC 37.1 -40 to 105/125
3×0.75 24 0.21 1.15 1.75 5.30 C PVC PVC 24.7 -40 to 105/125

2×0.5+

DW

19 0.19 0.90 1.55 4.50 B PVC PVC 37.1 -40 to 105/125
4×0.35+DW 7 0.26 0.80 1.25 4.50 B PVC PVC 54.4 -40 to 105/125
3×0.35+DW 7 0.26 0.75 1.25 4.50 B PVC PVC 54.4 -40 to 105/125
Special Cable shielded
2×0.25 32 0.11 0.60 1.20 4.20 C TPE-E TPE-U 70.3 -40 to 125/150
2×0.35+DW 7 0.26 0.75 1.35 4.90 B PP PVC 54.4 -40 to 90/105/125
3×0.35 Flex 45 0.11 0.80 1.25 3.50 C PVC TPE-U 54.4 -40 to 105/125

Disclaimer :

REACH compliance should be considered as customer specific requirement and must be specified at time enquiry if required. The information contained in this datasheet is for guidance only and is subject to change without notice or liability. All the information is provided in good faith and is believed to be correct at the time of publication. When selecting the cable accessories, please note that actual cable dimensions may vary due to manufacturing tolerances.