UL-1007, Single Core UL-1007 80°C Cables

Single Core UL-1007

Applications

  • Appliance wiring material (AWM)
  • Internal wiring of meters, panels, Machine Tool electrical & electronic equipment, In Machine Laid, In protective tubes, flexible pipes and also for Motors and Transformers.
Single Core UL-1007 Product Construction

Features

  • PVC self – extinguishing and flame retardant, test method to UL VW-1 and CSA FT 1 / FT 2
  • Rated for Continuous use up to 60°C or 80°C in oil and 105°C in Dry.
Balajiwires Quick Quote

Technical Data

Standard UL – Std. 758. Complies to CSA No. 22.2 210
Nominal Voltage 300 V
Test Voltage (Spark Test) AWG 28 to 24 → 4 kV (DC)
AWG 22 to 20 → 5 kV (DC)AWG 18 to 16 → 6 KV (DC)
≥ AWG 8 → 7.5 kV (DC)
Temperature Range Flexible -5°C to +80°C

Fixed Installation  -20°C to +80°C

Temperature at Conductor Max. UL and CSA : +80°C
Bending Radius Flexing 10 x Cable ø .Fixed Installation 5 x cable ø
Download Product Details

Certifications & Compliance

Single Core UL-1007 Certifications & Compliance

Cable Design Parameters

AWG Metric Cross Sectional Area (Sq. .mm ) No of Strand /Strand Diameter (mm) Approx. Diameter of Conductor Average Insulation Thickness Minimum Insulation Thickness Nominal Cable Diameter
28 0.084 7/0.13 0.385 0.382 0.33 1.20
26 0.134 7/0.16 0.485 0.382 0.33 1.30
24 0.211 7/0.20 0.610 0.382 0.33 1.40
24 0.211 11/0.16 0.610 0.382 0.33 1.40
22 0.333 7/0.25 0.760 0.382 0.33 1.55
22 0.333 17/0.16 0.760 0.382 0.33 1.55
20 0.521 7/0.31 0.950 0.382 0.33 1.75
20 0.521 67/0.1 0.950 0.382 0.33 1.75
20 0.521 26/0.16 0.950 0.382 0.33 1.75
18 0.823 16/0.26 1.20 0.382 0.33 2.00
18 0.823 73/0.12 1.20 0.382 0.33 2.00
18 0.823 41/0.16 1.20 0.382 0.33 2.00
16 1.317 26/0.26 1.55 0.382 0.33 2.35
16 1.317 65/0.16 1.55 0.382 0.33 2.35

Disclaimer :

REACH compliance should be considered as customer specific requirement and must be specified at time enquiry if required. The information contained in this datasheet is for guidance only and is subject to change without notice or liability. All the information is provided in good faith and is believed to be correct at the time of publication. When selecting the cable accessories, please note that actual cable dimensions may vary due to manufacturing tolerances.